Installation (for qualified installers only) – Avalon Stoves 21 DV Fireplace User Manual
Page 10

10
Installation (for qualified installers only)
© Travis Industries
4040830
100-01143
Nailing Brackets
For installations using 1”
facing (1/2” drywall with
3/8” tile, 7/8” tile, etc.)
fold the shorter tab out
90°.
For installations using
1/2” facing (1/2” drywall
or other facing) fold the
larger tab out 90°.
Fireplace
Drywall
Framing
1/8"
NOTE: When installed, there must be a minimum
1/8” gap between the face and facing.
Nailing Bracket
TOP VIEW
Tile
Fireplace
Drywall
Framing
1/8"
NOTE: When installed, there must be a minimum
1/8” gap between the face and facing.
Nailing Bracket
TOP VIEW
1/2” Facing
7/8” to 1” Facing
There are two nailing brackets on the
sides of the fireplace. Follow the
directions below to prepare the nailing
brackets. Once in place, nail or screw
the nailing brackets to the framing.