beautypg.com

Installation (for qualified installers only) – Avalon Stoves 21 DV Fireplace User Manual

Page 10

background image

10

Installation (for qualified installers only)

© Travis Industries

4040830

100-01143

Nailing Brackets

For installations using 1”
facing (1/2” drywall with
3/8” tile, 7/8” tile, etc.)
fold the shorter tab out
90°.

For installations using
1/2” facing (1/2” drywall
or other facing) fold the
larger tab out 90°.

Fireplace

Drywall

Framing

1/8"

NOTE: When installed, there must be a minimum
1/8” gap between the face and facing.

Nailing Bracket

TOP VIEW

Tile

Fireplace

Drywall

Framing

1/8"

NOTE: When installed, there must be a minimum
1/8” gap between the face and facing.

Nailing Bracket

TOP VIEW

1/2” Facing

7/8” to 1” Facing

There are two nailing brackets on the
sides of the fireplace. Follow the
directions below to prepare the nailing
brackets. Once in place, nail or screw
the nailing brackets to the framing.