Mantel Requirements
•
The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed below.
•
Use the table below to determine the maximum mantel depth allowed. For example, if a 6”
mantel is used, it must be a minimum of 6-1/2” above the face.
Maximum Mantel Depth (b)
Mantel
Height
Above
Face (a)
0”
1”
2”
8”
7”
6”
5”
4”
3”
9”
a
b
If you have a tapered mantel, measure the
mantel height at the point where it
protrudes 3/4” in front of the face.
0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10” 11” 12”
See “Face Dimensions”