beautypg.com

Vanguard ATO-600 User Manual

Page 30

background image

ATO-400 / ATO-600 Operating Procedures

30

6.6 Review Record Procedure

This procedure describes the steps for reviewing a test record residing in the ATO’s working
memory. The user can view the record on the LCD display.
This feature is useful when the user wants to review a test record stored in the ATO’s Flash
EEPROM in the field or in the office.

NOTE

To review a test record stored in Flash EEPROM, the user must first restore the test record from
Flash EEPROM to working memory (see paragraph 7.1.9 Restore Record Procedures).

Table 8.0 Review Record Procedure

STEP

ACTION

ATO DISPLAY

8-1

On the START MENU, press key #2
(SETUP) to select the SETUP MENU (shown
at right).

8-2

Press key #2 (REVIEW RECORD).
The user can scroll through the test record by
using the ^ and

?

keys.

8-3

Part of the selected record’s ID appears
displaying the record number,
MANUFACTURER, and MODEL. Press the
“ENTER” key to display the number of tests
in the record, the date, and the time of the
selected tests.

8-4

Pressing the “ENTER” key will list all test
data: Test current, burn-in time, and the
measured resistance value.

NOTE

The test record in this example contains 2
tests.

8-5

Press

?

key to advance to next test. Press

?

key to return to previous test.

8-6

Press STOP to return to START MENU.

Display returns to START MENU

.

This completes the Review Record Procedure.

1. ENTER ID
2. REVIEW RECORD
3. RESTORE RECORD
4. NEXT PAGE

RECORD ID INFO:

1710
VIC
ABC

2 TESTS

04/11/05 17:27:00

TEST NUMBER: 1

TEST CURRENT: 100A
BURN - IN TIME: 5 Sec

500.3 MICRO-OHMS

TEST NUMBER: 2

TEST CURRENT: 50A
BURN - IN TIME: 5 Sec

500.1 MICRO-OHMS

This manual is related to the following products: