Table 6.0 Run Test Procedure (Measure an Unknown Resistance Continued)

STEP

ACTION

ATO DISPLAY

6-5

Press the START key to run a resistance
measurement test. Percent of ramp level
displays with the notice TEST IN
PROGRESS. When the test current has
ramped up to the specified level (current is
at 100%), the test result displays
automatically.

6-6

Automatic, no operator action required.
Current, burn-in time, and resistance
measurement changes appear on the display
during burn-in. At the end of the burn-in
time, the current returns to zero.

6-7

Automatic, no operator action required. At
the end of the burn-in time the final
resistance displays.
To initiate another test, disconnect then
reconnect one or both sense cables, steps 6-
5 to 6-7 will be repeated (witout having to
press the START key in step 6-5).
To end Automatic test mode, press the
STOP key.

6-8

Pressing the STOP key will end the
Automatic test mode and the “SAVE THIS
RECORD” message is displayed.

6-9

To save this record, press key #1 (YES). If
the test record is not to be saved, press key
#2 (NO) and go to step 6-11.

NOTE

A test record is saved in Flash
EEPROM. A record number
will be automatically assigned
to the record by the ATO. (The
Test record was assigned #2 in
this example).

6-10

When a record is saved (the record #
assigned shows on display), press ENTER
to return to the START MENU.

AUTO TEST MODE

RAMPING CURRENT 10%

TEST IN PROGRESS

PLEASE WAIT

AUTO TEST MODE

BURN-IN: AUTO

500.5 MICRO-OHMS

PLEASE WAIT

FINAL RESISTANCE
I= 100 AMPS
500.5 MICRO-OHMS
AUTO TEST MODE

SAVE THIS RECORD?
1. YES
2. NO

RECORD NUMBER 2
HAS BEEN SAVED!

1. RUN TEST 04/11/05
2. SETUP 12:24:01
3. DIAGNOSTIC