beautypg.com

Troubleshooting – TIF 5650A Halogen Leak Detector User Manual

Page 11

background image

* Remember that a worn out tip, no matter how clean, is still worn out and
will result in poor unit performance.

** Battery condition can be judged by checking the power indicator light
on the front of the unit. Weak batteries may cause the light to "blink".
Good batteries will result in a steady light.

NOTE: It is best to measure the battery voltage, as indicated in the
maintenance section on page 8, before reaching a conclusion.

TROUBLESHOOTING

9

PROBLEM

Erratic and/or
continuous
beeping signal

Erratic and/or
continuous
beeping signal

Reduced
sensitivity

Reduced
sensitivity

Probe pump

runs but unit

does not beep

Unit will not
detect a
known leak

Unit will not
detect a
known leak

Unit will not
detect a
known leak

Unit will not
detect a
known leak

CAUSE

Dirty tip
or
protector

Low battery
condition

Tip is worn
out

Dirty tip or
protector

Batteries
reversed

Tip is worn
out

Low battery
condition

Turned on in
presence of
a leak

Dirty tip
or Protector

CORRECTION

Replace or *
clean tip
or protector

Check pwr light **
& voltage. Replace
batteries if needed

Replace tip

Replace or clean *
tip or protector

Remove and
correct

Replace tip

Check power light**
& voltage. Replace
batteries if needed

Reset unit in a
clean atmosphere
(see page 6)

Clean or *
Replace tip
or Protector

This manual is related to the following products: