beautypg.com

Specific to “tx cem test” group, Specific to “rx calibration and test” group, Specific to “rx cem test” group – Teledyne LeCroy QPHY-PCIe3-Tx-Rx User Manual

Page 25

background image

QPHY-PCIE3-TxRx

Operator’s Manual

923662 Rev B

21

T

EST

M

ODE

This variable can be set to

“AquireNewData” or “UseSavedData”. For RX calibration, this MUST

be set to “AcquireNewData”.

Specific to “TX CEM test” Group

N

UM

L

ANES

T

X

This variable determines how many lanes will be tested for Tx compliance:

Single lane devices: only lane 0 is tested

Four lane devices: lanes 0 and 3 are tested

Eight lane devices: lanes 0, 3 and 7 are tested

Sixteen lane devices: lanes 0, 7, and 15 are tested

Specific to

“Rx Calibration and test” Group

P

E

RT3

N

AME

This variable will identify the PeRT that is being calibrated. This can be the PeRT's serial
number or any string that can be used to make a folder name for RX calibration results.

P

E

RT3

A

DDRESS

This variable is the hostname or IP address of the PeRT3 Server (the machine that the PeRT is
connected to via USB), from the point of view of the oscilloscope that QualiPHY is
communicating with. So: "localhost" refers to the oscilloscope that QualiPHY is communicating
with, which is not necessarily the machine QualiPHY is running on. The expected configuration
is that the PeRT3 is connected by USB to the oscilloscope, and therefore PeRTAddress should
be set to “localhost”. The script communicates with the PeRT through the oscilloscope.

Specific to

“Rx CEM Test” Group

P

ROMPT

T

O

R

ESET

DUT

True by default. This prompts you to reset or turn off and on the DUT before each attempt to
traverse the state machine to get to Loopback. For many DUTs this is required.

S

EARCH

A

ROUND

P

RESET

True by default. If this variable is False, then the RX test is only done exactly at the preset you
select, and if it does not succeed then a failure is declared. If this variable is True, then if the
RX test exactly at the preset you select does not succeed, the test varies de-emphasis and
preshoot searching for the best BER and giving your DUT the best opportunity to pass at some
TX EQ settings somewhere close to the selected preset.

SKP_F

ILTER

[O

N

|O

FF

]

SKP Filter option is needed for testing DUTs operating with the system/add-in card running on
different clock domain than the test equipment. This option can also be enabled for synchronous
test setups where the DUT is enabled to filter SKP symbols.