16

923662 Rev B

Add-in Card Tx

This configuration will run the Add-in Card Tx compliance tests using the CBB3 fixture. Tx
Compliance tests are performed using the SigTest software. SigTest uses raw waveforms (.trc)
from the oscilloscope, embeds the reference channel, and applies the CTLE/DFE filter.
Predefined configurations exist for testing 1, 4, 8, and 16-lane devices.

The test items are:

Min Transition Eye Height

Min NonTransition Eye Height

Composite Eye Height

Mean UI

Max Pk-Pk Jitter

Min Eye Width

Tj

Djdd

Rj

P

HYSICAL

S

ETUP

Figure 9

– Add-In Card Tx connection diagram showing oscilloscope (green) and Rx Ln0 (blue)