7.1.9 IRecOptions::SetSaveExternalSignals


HRESULT SetSaveExternalSignals (

[in] BOOL save );


Sets the flag indicating to save external signals.


Parameters

save

TRUE saves external signals.
FALSE does not save external signals.

Return values


Remarks


By default, external signals are not saved.

Example


WSH:

CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName, "\"))
Set Analyzer = WScript.CreateObject("CATC.USBTracer")
Set RecOptions = Analyzer.GetRecordingOptions
RecOptions.SetSaveExternalSignals TRUE

C++: