Maintenance, Maintenance chart, Batteries – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual
Page 50
48
NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• It is suggested that while at the site voltage readings be taken at the operator.
Using a digital voltmeter, verify that the incoming voltage to the operator is
within ten percent of the operator’s rating.
MAINTENANCE CHART
Disconnect all power (AC, solar, battery) to the operator before servicing. The operator's AC Power switch ONLY turns off AC power to the control board and
DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator.
MAINTENANCE CHART + BATTERIES
MAINTENANCE
DESCRIPTION
TASK
CHECK AT LEAST ONCE EVERY
MONTH
6 MONTHS
3 YEARS
Entrapment Protection Devices
Check and test for proper operation
X
Warning Signs
Make sure they are present
X
Manual Disconnect
Check and test for proper operation
X
Sprockets and Chains
Check for excessive slack and lubricate
X
Gate
Inspect for wear or damage
X
Accessories
Check all for proper operation
X
Electrical
Inspect all wire connections
X
Chassis Mounting Bolts
Check for tightness
X
Operator
Inspect for wear or damage
X
Batteries
Replace
X
BATTERIES
Batteries will degrade over time depending on temperature and usage. The operator
alarm will beep 3 times with a command if the battery is low. Batteries do not
perform well in extremely cold temperatures. For best performance, the batteries
should be replaced every 3 years. Use only LiftMaster part 29-NP712 for
replacement batteries. The operator comes with two 7AH batteries. Two 33AH
(A12330SGLPK), 33AH Battery Harness (K94-36596) with additional battery tray
(K10-36183) may be used in place of the 7AH batteries.
The batteries contain lead and need to be disposed of properly.
NOTE: If your application includes a heater, two 33AH will not fit into the operator