Introduction, Operator specifications, Carton inventory & operator dimensions – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual
Page 10

8
INTRODUCTION
OPERATOR SPECIFICATIONS + CARTON INVENTORY & OPERATOR DIMENSIONS
OPERATOR SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:
Gate Classifications: CLASS I, II, III, & IV
Main AC Supply: 120 Vac or 240 Vac
Solar Power Max: 24 Vdc at 60 watts max.
Input Rating:
• CSW24V: 10 Amps at 120 Vac or 2 Amps at 240 Vac
• CSW24VH: 12 Amps at 120 Vac
Input Rating Excluding Accessory Outlets:
• CSW24V: 4 Amps at 120 Vac or 2 Amps at 240 Vac
• CSW24VH: 6 Amps at 120 Vac
*Input Rating of Accessory Outlets: 6 Amps at 120 Vac
*NOTE: The accessory outlets are not connected for the 240 Vac rating.
Main Supply (Motor): 24 Vdc
Accessory Power: 24 Vdc 500 mA Max for ON or SW (switched)
NOTE: Increased accessory power drawn from the operator will shorten the battery
back-up duration or decrease cycle count for solar applications.
Full Cycle Time: 40 seconds (90 degree opening and closing)
Maximum Travel Range: 115 degrees
Heater Draw (Optional): 325 watts (120 Vac ONLY)
Maximum Gate Weight/Length:
• 1200 lbs./12 foot
• 800 lbs./16 foot
• 600 lbs./18 foot
Daily Cycle Rate AC power: Continuous duty
Ambient Temperature:
• Without Heater: -20°C to 60°C (-4°F to 140°F)
• With Heater: -40°C to 60°C (-40°F to 140°F)
Fuse Protection Battery: 30 Amp
Fuse Protection DC Power: 30 Amp
CARTON INVENTORY & OPERATOR DIMENSIONS
NOT SHOWN: Documentation Packet
Operator
Arm Assembly
Cover
27.66”
18.77”
14.6”
Warning Signs (2) and Warranty Card
Battery 12 Vdc 7AH (2)
Key (2)