Troubleshooting, Control board leds, Limit setup leds – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual
Page 42: Green xmitter led
40
CONTROL BOARD LEDS
The control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the operator, assist with programming, and
diagnose potential problems with the operator.
NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug.
CONTROL BOARD LEDS
TROUBLESHOOTING
STATUS LEDS
LIMIT SETUP LEDS
SET OPEN
LED
SET CLOSE
LED
OPERATOR MODE
EXPLANATION
BLINKING
BLINKING
NORMAL MODE
Limits are not set.
OFF
OFF
NORMAL MODE
Limits are set.
BLINKING
BLINKING
LIMIT SETTING MODE
Limits are not set.
BLINKING
ON
LIMIT SETTING MODE
Open limit is not set.
ON
BLINKING
LIMIT SETTING MODE
Close limit is not set.
ON
ON
LIMIT SETTING MODE
Limits are set.
LIMIT SETUP LEDS
GREEN XMITTER LED
DIAGNOSTIC CODES LEDS
INPUT LEDS
YELLOW NETWORK LED
GREEN XMITTER LED
XMITTER LED
EXPLANATION
OFF
No remote control activity, normal operation.
ON
Programming mode active.
ON (for 1 second)
Recognized remote control signal.
ON (for a 1/4 of a second)
Unrecognized remote control signal.
ON (8 blinks per second)
Remote controls are being erased.