Startup – LEESON FHP Series NEMA 4x Variable Speed Drive User Manual
Page 33

24
Startup
1. Verify that no conductive material is present on the PCB.
2. Verify that the correct voltage is connected to the inputs
before applying power. DO NOT CONNECT 230 VAC
line voltage to a 115 VAC configured drive. Applying
power in this manner will damage the motor and drive.
3. Set the speed adjust potentiometer or reference signal
to zero (full CCW).
4. Set the DIRECTION switch (if installed) to the desired
direction. If no switch is installed, add or remove a
jumper across the (D) and (E1) terminals, as required.
5. Apply 115 or 230 VAC, 50/60 Hz, single-phase power to
the drive. The green POWER LED will come on after an
initial delay of 1 - 2 seconds. If the POWER LED does
not light, check the line fuses to ensure that they are
properly installed and not open.
Warning
DO NOT change jumper settings with power
applied. Ensure that jumper settings are compatible
with the motor being controlled.
Before applying power, verify that no conductive
material is present on the printed circuit board.
ƽ