To prevent damage to the GFEP device and to provide strain
relief to the cord, use cable ties to secure the device to the
wall near the receptacle. Be careful not to damage either the
cord or the ground-fault unit.

Note: Pipe must be fully insulated.

Cable

ties

Pipe freeze protection

Pipe freeze protection

Cord label

Plug the heating cable into a 15 amp, 120-Vac grounded
outlet.

Make sure that:
– The cord label is visible.
– The indicator light on the ground-fault equipment

protection device is on.

– The receptacle is properly weatherproofed (if outdoors).
– The ground-fault equipment protection device and the

power connection splice will not be submerged.

Roof and gutter de-icing

Roof and gutter de-icing

To prevent damage to the ground-fault equipment
protection device and to provide strain relief, use clamp
ties to secure the device to the wall near the receptacle.
Be careful not to damage either the cord or the ground-
fault unit.

The SRK08 should be mounted high up, away from
persons to prevent damage to the unit and the risk of
shock

Cable

ties

Cord label

Deicing

label

Plug the heating cable into a 15 amp, 120-Vac grounded
outlet approved for wet locations.

Make sure that:
– The cord label is visible.
– The indicator light on the ground-fault equipment

protection device is on.

– The receptacle is properly weatherproofed.
– The ground-fault equipment protection device and power

connection splice will not be submerged.