King Electric SRK08 GFEP device kit User Manual
Page 16
![background image](/manuals/350888/16/background.png)
Rev 11.04.12
www.king-electric.com
16
To prevent damage to the GFEP device and to provide strain
relief to the cord, use cable ties to secure the device to the
wall near the receptacle. Be careful not to damage either the
cord or the ground-fault unit.
Note: Pipe must be fully insulated.
Cable
ties
Pipe freeze protection
Pipe freeze protection
Cord label
Plug the heating cable into a 15 amp, 120-Vac grounded
outlet.
Make sure that:
– The cord label is visible.
– The indicator light on the ground-fault equipment
protection device is on.
– The receptacle is properly weatherproofed (if outdoors).
– The ground-fault equipment protection device and the
power connection splice will not be submerged.
Roof and gutter de-icing
Roof and gutter de-icing
To prevent damage to the ground-fault equipment
protection device and to provide strain relief, use clamp
ties to secure the device to the wall near the receptacle.
Be careful not to damage either the cord or the ground-
fault unit.
The SRK08 should be mounted high up, away from
persons to prevent damage to the unit and the risk of
shock
Cable
ties
Cord label
Deicing
label
Plug the heating cable into a 15 amp, 120-Vac grounded
outlet approved for wet locations.
Make sure that:
– The cord label is visible.
– The indicator light on the ground-fault equipment
protection device is on.
– The receptacle is properly weatherproofed.
– The ground-fault equipment protection device and power
connection splice will not be submerged.