King Electric N.E.M.A.4X TH109 User Manual
Warning, Caution, Warning advertencia avertissement
WARNING
To prevent overheating or fire, use this control as an operating or regulating
thermostat. ALWAYS USE A BACKUP CONTROL OR ALARM if a control
failure could cause the controlled appliance to overheat or could cause a fire
Where thermostat is capable of cycling directly between heating and cooling
loads, failure to provide a load transfer switch will result in thermostat failure.
Do not install, use or operate if product appears damaged, the enclosure is
cracked or broken or if the sensor has been bent, crimped or is dirty.
APPROPRIATE APPLICATION
This thermostat has been tested by CSA and Underwriters Laboratories Inc.
(UL), meets the requirements for NEMA 4X equipment and is suitable for use
under the National Electrical Code (NEC), Article 547-7, when used with
appropriate watertight connectors (not included).
INSTALLATION
Installation must be made by a trained, qualified service person in accordance
with the National Electrical Code (NEC) and all applicable local codes and
ordinances. Installation should meet all applicable national, state and local
codes. Refer to the appropriate wiring diagram included. Locate the thermostat
( local sensing models ) or sensing bulb ( remote sensing models ) for optimum
temperature sensing of the controlled space. Thermostat operation will be
affected by unusual heat or cold, such as direct sunlight, near windows or doors
or on outside walls.
All fittings and materials used for the installation should be approved, suitable
and installed properly for the intended application. For water tightness, the cord
seal or conduit hub should be UL listed and marked 4X. The conduit hub is to be
tightened onto the conduit before installing in the enclosure.
Where applicable, remove knockout(s) by impacting near the inside edge of the
knockout to be removed. IMPORTANT: Do not impact, dent or use the
sensor for support. This will cause calibration and/or thermostat failure.
To avoid electrical shock or damage to equipment, disconnect all power
before installing or servicing.
To avoid potential fire and/or explosion, do not use in potentially flammable or
explosive atmospheres.
WARNING
WARNING
READ
INSTRUCTION
CAREFULLY
BEFORE
ATTEMPTING
TO
INSTALL, OPERATE OR SERVICE THIS THERMOSTAT.
Failure to
observe safety information and comply with instructions could result in
PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE.
Retain these instructions for future reference. This product, when installed,
will be part of an engineered system whose specifications and performance
characteristics are not designed or controlled by PECO. You must review
your
application
and
national
and
local
codes
to
assure
that
your
installation will be functional and safe.
Even though this thermostat is sealed, water or dust could enter through
improperly sealed wiring. A drip loop should be provided to prevent water and
other liquids from entering the thermostat housing. The cord or conduit
connections to the enclosure must be water and dust tight. The cover must be
tightened securely to compress the gasket and provide a watertight seal. Use
only screws provided. Do not over-tighten.
Maximum sensing element withstand temperature is 35°F (20°C) above the
highest temperature setting. Maximum temperature for the plastic enclosure is
140°F 60°C.
OPERATION AND CHECK-OUT
Allow one hour or necessary amount of time for the thermostat and system to
stabilize for normal operation. This thermostat is factory calibrated and
requires no correction on site.
TO CHECK OPERATION OF HEATING SYSTEMS:
1.
Disconnect power.
2.
Place the heat/cool selector switch, if applicable, in the heat position.
3.
Adjust
the
thermostat
set
point
to
at
least
10°F
(5°C)
below
the
temperature of the controlled space.
4.
Restore power.
5.
Slowly adjust the thermostat knob to raise the set point. When the set
point reaches the approximate temperature of the controlled space, the
heating equipment should start.
TO CHECK OPERATION OF COOLING SYSTEMS:
1.
Disconnect power.
2.
Place the heat/cool selector switch, if applicable, in the cool position.
3.
Adjust the thermostat set point to at least 10°F (5°C) above the
temperature of the controlled space.
4.
Restore power.
5.
Slowly adjust the thermostat knob to lower the set point. When the set
point reaches the approximate temperature of the controlled space, the
cooling equipment should start.
For use in wet or humid environments or where water tightness is required,
failure to use suitable watertight connections and suitable drip loop could
allow water to enter the enclosure resulting in thermostat failure.
Use copper wire only. Insulate or wire-nut all unused leads.
Use the grounding provisions provided for connection to the line ground
and equipment ground wire.
LIMITED WARRANTY
1. WARRANTY COVERAGE. PECO warrants to the original user of its products that the
products will, at the date of initial purchase, meet the applicable specification for such
products and will be free from any defects in materials or manufacture under normal use
for 18 months after date of manufacture.
2. DISCLAIMER OF WARRANTY OF PRODUCT SUITABILITY. PECO makes no
warranty to the purchaser or any third party that its products are suitable for a particular
application or design. Many states and localities have differing codes or regulations
governing the installation and/or use of PECO' products. PECO cannot guarantee
compliance with such regulations; purchaser is solely responsible for safe and correct
installation and use of the product and for compliance with applicable codes and
regulations.
3. EXCLUSION OF IMPLIED WARRANTIES. This warranty is the only warranty
applicable to this product and excludes all other warranties, including any WARRANTY OF
MERCHANTABILITY, any warranty of fitness for a particular purpose, and any implied
warranties otherwise arising from course of dealing or usage of trade, except where the
product purchased is subject to consumer product warranty laws, in which case ANY
APPLICABLE IMPLIED WARRANTIES ARE LIMITED TO 18 MONTHS, or such shorter
period as permitted or required under applicable law.
Some States do not allow limitations on how long an implied warranty lasts, so the above
limitations may not apply to you.
4. REMEDIES FOR NONCONFORMITY. If the product purchased does not conform to the
applicable warranty, PECO will provide, at its option and in accordance with the
procedures in the following section, one of the following remedies: (1) repair of the
nonconforming product, (2) replacement with a conforming product, (3) refund of the
original purchase price. THESE REMEDIES SHALL BE THE EXCLUSIVE AND SOLE
REMEDY for any breach of warranty.
5. TO OBTAIN WARRANTY SERVICE. For any product believed to be defective within the
limited warranty period, first write or call dealer from whom product was purchased.
Dealer will give additional directions. If unable to resolve satisfactorily, write to PECO at
the address below, giving dealer's name, address, date and number of dealer's invoice,
and describe the nature of the defect.
6. LIMITATION OF LIABILITY. PECO WILL NOT BE LIABLE FOR ANY INCIDENTAL,
SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES resulting from any defect in the
product purchased. Some States do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which
vary from State to State.
Manufactured by PECO, Inc.
4709 SE 18th Avenue - Portland, OR 97202 - USA
P.O. Box 82189 - Portland, OR 97282 - USA
NEMA 4X RAINTIGHT THERMOSTAT
INSTALLATION AND OPERATING INSTRUCTIONS
INSTRUCCIONES DE INSTALACION Y OPERACION
DEL THERMOSTATO A PRUEBA DE LLUVIA NEMA 4X
THERMOSTAT NEMA 4X ÉTANCHE AUX INTEMPÉRIES
INSTRUCTION D'INSTALLATION ET D'UTILISATION
CAUTION
© COPYRIGHT 2002 PECO, Inc. ALL RIGHTS RESERVED
BLACK
NEGRO
NOIR
BLUE
AZUL
BLEU
RED
ROJO
ROUGE
L1
COOLING LOAD
CARGA DE ENFRIAMIENTO
CHARGE DE REFROIDISSEMENT
HEATING LOAD
CARGA DE CALEFACCION
CHARGE DE CHAUFFAGE
LT
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
YELLOW
AMARILLO
JAUNE
VIOLET
VIOLETA
VIOLET
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
BLACK
NEGRO
NOIR
L1
AUXILLARY LEAD
CONDUCTOR AUXILIAR
CONDUCTEUR AUXILIAIRE
BLUE
AZUL
BLEU
HIGH
ALTO
HAUT
LOW
BAJO
BAS
VIOLET
VIOLETA
VIOLET
BROWN
CAFÉ
MARRON
L1
BLUE
AZUL
BLEU
L2 OR NEUTRAL
L2 O NEUTRO
L2 OU NEUTRE
BLACK
NEGRO
NOIR
L1
LT
RED
ROJO
ROUGE
PINK
ROSADO
ROSE
SECOND STAGE COOLING
ENFRIAMIENTO DE SEGUNDA ETAPA
REFROIDISSEMENT SECOND ÉTAGE
FIRST STAGE HEATING
CALENTAMIENTO DE PRIMERA ETAPA
CHAUFFAGE PREMIER ÉTAGE
FIRST STAGE COOLING
ENFRIAMIENTO DE PRIMERA ETAPA
REFROIDISSEMENT PREMIER ÉTAGE
SECOND STAGE HEATING
CALENTAMIENTO DE SEGUNDA ETAPA
CHAUFFAGE SECOND ÉTAGE
FIELD WIRING
CABLEADO EN EL TERRENO
CABLAGE SUR PLACE
THERMOSTAT WIRING
CABLEADO DEL TERMOSTATO
CABLAGE DU THERMOSTAT
INDICATES SEQUENCE ON
TEMPERATURE RISE
INDICA LA SECUENCIA CUANDO LA
TEMPERATURA SE
INDIQUE LA SE SÉQUENCE DE LA MONTÉE
DE TEMPÉRATURE
LOAD TRANSFER SWITCH
INTERRUPTOR DE TRANSFERENCIA DE CARGA
INTERRUPTEUR DE TRANDFERT DE CHARGE
LEGEND
LEYENDA
LÉGENDE
LT
LT
TH109
TJ109 MODELS
T115 TA119 TC109 TC119
-REMOVE AND DISCARD
THE CENTER OF THE GASKET
-EXTRAIGA Y DESCARTE
LA PARTE CENTRAL DE LA JUNTA
-ENLEVER LE CENTRE DU
JOINT ET LE METTRE AU REBUT
-TO INSURE WATER TIGHTNESS, THE ENCLOSED GASKET MUST BE
INSTALLED UNDER THE WIRING CAP.
- PA R A
A S E G U R A R
L A
E S TA N Q U I D A D
A L
A G U A ,
L A
J U N TA
SUMINISTRADA DEBERÁ INSTALARSE DEBAJO DEL CASQUETE DEL
ALAMBRADO.
-POUR
ASSURER
L'ÉTANCHÉITÉ
À
L'EAU,
LE
JOINT
STATIQUE
(FOURNI) DOIT ÊTRE INSTALLÉ SOUS LE CULOT POUR CÂBLAGE.
WARNING
ADVERTENCIA
AVERTISSEMENT
PAGE 4
P/N 68087 / 3220-1188 / REV 0 / PAGE 1