King Electric TH114-AF-GA Electronic Non-Progrm User Manual
Description, Configuration, Installation
08162 / TH114-A-240D / TL7235
69-2022-1 2007-10-17 1/2
Non-programmable Thermostat - Installation and User Guide
This thermostat can be connected to an electric heater to control the
room temperature.
*
The thermostat indicates how much heating is required to maintain the desired
temperature. For example,
is displayed when heating is at 40 percent.
The configuration switch is located at the back of the control module
(faceplate). The switch allows you to select between °C and °F
Turn off power to the heating system at the main electrical panel
to avoid electrical shock. The installation should be carried out
by an electrician.
High voltage thermostats must be installed onto an electrical
box.
For a new installation, choose a location about 5 ft. above the
floor and on an inside wall.
The thermostat must be installed on an inside wall facing the
heating system.
Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or con-
cealed chimneys or stove pipes.
n
Connect the power base wires to the power supply and load
using solderless connectors for copper wires.
o
Push the excess length of the high-voltage wires back into the
electrical box.
p
Secure the power base to the electrical box using the provided
screws.
q
Install the control module onto the base.
r
Apply power to heating system.
NOTE:
Always keep the thermostat's vents clean and unobstructed.
As soon as the thermostat is powered, it undergoes a
series of tests before displaying the actual temperature.
LO: The measured temperature is below the display
range. Heating is activated.
HI: The measured temperature is above the display
range.
n
Description
1.
Display
% of heating
1 to 24%
25 to 49% 50 to 74% 75 to 99%
100%
o
Configuration
2.
Backlight button
Temperature
adjustment buttons
Set the switch to
Off to cut power to
the heater
Heating indicator *
Temperature
display
Appears when
the setpoint is
displayed
p
Installation
3.
q
Power-up
4.
r
Error Messages
5.
Power
Load
08162
TH114-A-240D
TL7235
400-114-014-B_69-2022-1 (Cadet TL7235) ENG.fm Page 1 Wednesday, October 17, 2007 8:58 AM