beautypg.com

KB Electronics KBPI-240DR User Manual

Page 19

background image

17

IX.

APPLICATION WIRING DIAGRAMS
Reversible Model KBPI-240DR (120/240 VAC)

Reversing models carry out the same functions as the unidirectional models except they can
be made to index in both the forward and reverse direction. A special circuit APRM

®

provides

a lockout feature that prevents catastrophic damage to the drive if a "Reverse" command is
given during "Forward" operation (and vice versa). The reversing drives contain two additional
positions on the terminal block: "Run Rev" and "Jog Rev." The stop logic command is made
with a normally closed (NC) contact.

Note: The sense of the stop logic can be changed from normally closed (NC) to
normally open (NO) by placing jumper JS in the "NO" position.

The following wiring diagrams illustrate typical logic circuits. Many other configurations are
possible. Consult factory if help is needed.

FIG. 17 – SEQUENCE OF CYCLE ON DEMAND OPERATION

1

2

3

4

5

6

RUN FWD

JOG FWD

STOP

RTN

+24V

COM

LS1

JOG REV

7

8

RUN REV

FIG. 17A – GENERAL

CONNECTION DIAGRAM

FIG. 17B – REVERSING

USING EXTERNAL CONTACTS

FIG. 17C – CYCLE ON DEMAND

WITH REVERSE

FIG. 17D – FORWARD AND REVERSE

CYCLE ON DEMAND

This manual is related to the following products: