3.11 Dome Communication
DOME ID
: Setting the dome camera address (ID) selection (1 ~ 3999)
PROTOCOL : AUTO, Fastrax II / IIE, Pelco-P / D
BAUD RATE : Setting the RS 485 Baud Rate (2400, 4800, 9600, 19200, 38400)
3.12 Alarm
Setup
NO : Alarm input number
PRI(Priority) : The lower number has higher priority. (0-8)
FUN(function) : Stored function number to be called by alarm.
IN
: X - ignore, ON - Enable
OUT : OUT1 ~ OUT2, OFF - No output.
HLD(HOLD) : Alarm will be held for programmed time (03 to 99 seconds)
LATCH : ON - Shows all alarms including past alarm.
OFF - Shows activated alarms only.
DWELL
:Means the dwell time during multiple alarms, 03 to 99 seconds.
The ALARM OUT setup is helpful when the outdoor housing is used with the dome.
Ex.) When you connect the relay output of the dome to the heater connector of the outdoor housing, the
relay output can operate during the setting time only.
DOME COMMUNICATION
DOME ID : 00XX
DOME ID : XX00
PROTOCOL : AUTO
BAUD RATE : 9600
PARITY : NONE
SAVE AND EXIT
ALARM SETUP
N P FUN IN O H L
01 1 001 X OFF 03 OFF
02 2 A01 X OFF 03 OFF
03 1 --- X OFF 03 OFF
04 1 --- X OFF 03 OFF
DWELL : 03
ALARM OUT SETUP
SAVE AND EXIT
ALARM OUT SETUP
OUT1 : ALARM
OUT2 : 1 MIN
EXIT