Harwin Z80-255 User Manual
Page 5
IS-27 Issue: 6 Date: 14.11.11 C/Note: 11542
Page 5 of 9
CRIMP INSPECTION (CONT.)
Crimp Inspection Areas
1. Insulation Inspection window
2. Bellmouth
3. Conductor Inspection window
4. Insulation crimp area
5. Conductor crimp area
6. Contact stop ear
Target
Insulation extends past Insulation
crimp area, but does not enter
Bellmouth.
Insulation crimp does not cut or
break Insulation.
Insulation crimp is fully wrapped
around and supporting insulation.
Conductors extend past conductor
crimp area, but not past contact
stop ear.
Acceptable
Insulation in-line with end of crimp
area.
Conductor in-line with end of crimp
area.
Insulation butted up to but not
entering bellmouth.
Conductor in-line with contact stop
ear, but not past.
1
2
3
4 5
6