Harwin C90 Braid Adaptors - Spring Band User Manual
Installation procedure for spring adaptor

INSTALLATION PROCEDURE FOR SPRING ADAPTOR
This instruction sheet is to aid in the assembly of the following MIL-DTL-5015 connectors to
braided cable:
C90-002-10SL
C90-002-12S
C90-002-14S
a) Prepare the cable making sure that a sufficient length of shield is available, so that it fits
against the front shoulder of the lip groove.
b) Before insertion of connector contacts, slide the heat-shrinkable connector boot onto the
cable, followed by the Spring Adaptor.
c) Position the heat shrinkable boot, Spring Adaptor, and braid out of the way, and insert the
connector contacts. Depending upon the shielding braid size it can either be folded back
onto itself or bunched up concertina style out of the way for easy access to the cable
conductors.
d) Slide the Spring Adaptor forward, over the braid, and pull the braid back so it is not
trapped under the Adaptor.
e) Screw the Spring Adaptor onto the connector and tighten to the torque value specified in
the table below. It is recommended that the connector threads are lubricated with a
suitable compound if a liquid thread lock is not used. The Adaptor should be hand
tightened to ensure proper thread alignment and then tightened with a strap wrench and
torque meter to the specified torque.
Tightening
Torque
Shell Size
(lb.in ±5)
(Nm ±0.5)
10SL 40 4.5
12S 40 4.5
14S 40 4.5
Harwin North America
Harwin Europe
Harwin Asia
T: +1 603 893 5376 F: +1 603 893 5396
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
T: +65 6 779 4909 F: +65 6 779 386 E:
[email protected] W: www.harwin.com
E: [email protected] W: www.harwin.com E: [email protected] W: www.harwin.com.sg
IS-31 Issue: 1 Date: 01.06.10 C/Note: ----
Page 1 of 2