beautypg.com

Harrington Hoists and Cranes TCS Hoist User Manual

Page 16

background image

16

3.6.5



Before connecting the hoist to its air supply line; perform the proper draining and

purging procedures to prevent contaminants or moisture from entering the hoist.

3.7

Mounting Location

3.7.1



Prior to mounting the hoist ensure that the suspension and it supporting structure

are adequate to support the hoist and its loads. If necessary consult a professional that is qualified to
evaluate the adequacy of the suspension location and its supporting structure.

3.7.2



See

Section 7.6

for outdoor installation considerations.

3.8

Connecting Hoist to Air Supply

3.8.1



HAZARDOUS AIR PRESSURE IS PRESENT IN THE HOIST, IN THE SUPPLY

OF COMPRESSED AIR TO THE HOIST, AND IN THE CONNECTIONS BETWEEN COMPONENTS.

3.8.2

Shut off the air supply and stop the airflow completely. Lock out and tag out in accordance with ANSI
Z244.1 “Personnel Protection -Lockout/Tagout of Energy Sources”.

Figure 3-4

Air Supply Connection to Hoist – Cord or Pendant Models

3.8.3



Before connecting the air supply hose to the hoist, always purge the air hose to

clear any debris and water.

3.8.4

Apply approximately 10-15 drops of turbine oil (see approved lubricant under

Section 6.0

Lubricants)

into the hose before attaching to the hoist.

3.8.5

Make connections to air supply; reference

Figure 3-4

. Use a reducing adapter at the hoist valve

section for hose sizes larger than 1/2”.

3.8.6



Where conditions dictate, the installation sequence can be reversed by mounting

the hoist first (

Section 3.9

) followed be connecting the air supply.

3.9

Mounting the Hoist

3.9.1

Manual Trolley - Follow instructions in Owner’s Manual provided with the trolley.

3.9.2