Leland Legacy Quick Guide

Terms »

Star button Ò
• Scrolls through run time data and Setup options

Up and down arrow buttons ST
• Toggle between display choices and increase or decrease sampling parameters in Setup

Button sequence
T

Ò= press buttons individually

[ST] = press simultaneously
ÒSTÒ

= security code, always press in sequence

Security code ÒSTÒ
• Prevents unauthorized changes to the pump’s sampling program

Programming Sequences »

• To activate pump (e.g., to change pump from Sleep to Hold):
Press any button.

• To change pump from Hold to Run or Run to Hold:
Press [ST].

• To reset accumulated data:
Press [ST], then ÒSTÒ. Press Ò until CLr displays then press [ST]; press Ò until End displays then

press [ST].

• To set pump fl ow rate:
Press [ST], then ÒSTÒ. Flow rate and SET fl ash. Press S or T to change fl ow rate. Press Ò until End

appears then press [ST] to save setting and place pump in Hold.

• To calibrate fl ow rate with standard calibrator:
Press [ST], then ÒSTÒ. Flow rate and SET fl ash. Press S or T to change fl ow rate. Press Ò once. ADJ

displays. Press S or T until desired fl ow rate is indicated on calibrator. When fi nished, press Ò until End displays
then press [ST] to save new setting and place pump in Hold. For CalChek Calibration, see operating instructions.

• To change temperature scale from F to C or C to F:
Press [ST], then ÒSTÒ. Press Ò until temperature displays. Press S or T to switch units; press Ò until

End displays then press [ST] to save new setting.

• To change atmospheric pressure scale (mm, mb, In):
Press [ST], then ÒSTÒ. Press Ò until pressure displays then press S or T to switch units; press Ò until

End displays then press [ST] to save new setting.

• To change time scale (12 Hr/24 Hr/Dela):
Press [ST], then ÒSTÒ. Press Ò until 12 Hr, 24 Hr, or Dela displays then press S or T to switch units;

press Ò until End displays then press [ST] to save new setting. To set delayed start (Dela), see operating
instructions.

• To change clock:
Press [ST], then ÒSTÒ. Press Ò until clock displays then press S or T to change fl ashing hour; press Ò to

move to minutes and S or T to change setting. Press Ò until End displays then press [ST] to save new setting.

• To change the sampling time function:
Press [ST], then ÒSTÒ. Press Ò until ST L/min displays then press S to change fl ashing digit; press Ò until

End displays then press [ST] to save new setting. To delete, follow above steps and press T until 0 appears.
Exit Setup.

Note: When in Setup, choosing Esc instead of End will exit Setup without saving new settings.