beautypg.com

Maintenance, Replacing the filter-drier – Robinair AC375C Refrigerant Recovery, Recycle, Recharge Unit User Manual

Page 29

background image

Recover/Recycle/Recharge Unit

27

Maintenance

The filter-drier inside the unit removes acid, particulates, and moisture from
refrigerant during the recovery function. To provide adequate contaminant
and moisture removal, the filter-drier must be replaced after every 68 kg
(150 lbs.) of refrigerant recovered. The following will appear in the display:

Use the following steps to replace the filter-drier.

NOTE: For maximum unit performance, use only SPX/ROBINAIR filter-driers.
To avoid service delays, keep extra filter-driers on hand. Refer to the Re-
placement Parts
section of this manual.

1. Plug the power cord into a correct voltage outlet.

2. Verify the service hoses are NOT connected to a vehicle.

Replacing the Filter-Drier

CHANGE FILTER

Control Panel

3. On the control panel, open both panel valves.

4. Press the Menu key (

) until RECOVER XX.XX displays on the screen.

5. Press the Start/Stop key ( ).

6. Watch the low-side gauge. When the gauge pressure reaches 34 kPa

(10 in. Hg) vacuum, close both panel valves.

7. Press the Start/Stop key ( ).

8. Remove the power cord from the outlet.

Start/Stop Key

Oil Drain Valve

Display Screen

Menu Key

Up Arrow

Down Arrow

ISV Pressure

Gauge

Low-Side

Gauge

High-Side

Gauge

Low-Side

Panel Valve

High-Side

Panel Valve /

Oil Inject

Power Switch