Initial setup, Adding vacuum pump oil contd – Robinair AC375C Refrigerant Recovery, Recycle, Recharge Unit User Manual
Page 11

Recover/Recycle/Recharge Unit
9
7. With the vacuum pump running, slowly add oil until the level rises to
the center of the oil sight glass.
NOTE: The pump holds approximately 237 mL (8 ounces) of oil.
8. When the vacuum pump countdown reaches zero, the vacuum pump
stops, and the unit display changes to the recover function.
9. Replace the plastic plug in the oil fill port.
After adding oil to the vacuum pump, add refrigerant to the internal
storage vessel. Refer to the instructions on the next page.
Note: The unit’s
weight default is in
kilograms. To change
the default to pounds:
1. Press the Up and
Down arrow keys
at the same time.
will be displayed.
2. Press the Up or
Down arrow key to
toggle to LBS.
3. Press the Menu
(
)
key until the
display reads EXIT.
4. Press Start/Stop
( )
key to exit.
UNITS KG
Initial Setup
Adding Vacuum Pump Oil contd.