Initial setup – Robinair AC375C Refrigerant Recovery, Recycle, Recharge Unit User Manual
Page 13
Recover/Recycle/Recharge Unit
11
R-12 refrigerant users start with Step 3.
1. Connect the blue R-134a coupler to the blue hose and the red R-134a
coupler to the red hose as shown.
2. Connect the low-side tank adapter (from the accessory kit) to the liquid
valve on the refrigerant source tank. NOTE: If using a refillable source
tank, connect the tank adapter to the vapor valve.
R-134a Tank Adapter
3. Connect the service coupler of the low-side hose (blue) to the refrigerant
source tank.
4. Open the valve on the source tank, and place the tank upside down in the
source tank compartment. Secure the source tank in place by wrapping
the strap around the tank and then fastening the strap.
5. The screen should display RECOVER XX.XXKG.
If it does not, scroll through the functions, pressing the Menu key (
) until
RECOVER XX.XXKG is displayed.
6. Press the Arrow keys to adjust the recover weight to 7 kg (15 lbs.).
R-134a Coupler
Initial Setup
Adding Refrigerant to the Internal Storage Vessel contd.