6

Set Tank Fill Level

The .operator .may .either .accept .the .unit’s .pre-set .default .

weight .of .15 .lbs . .(6 .8 .kg) .of .refrigerant .stored .in .the .

internal .storage .vessel .(ISV), .or .change .the .amount .to .

accommodate .the .application .
The .unit .displays

LEVEL: .15 .00 .LBS .

ENTER .TANK .FILL .LVL

LIMIT: .4 .TO .17 .LBS .

PRESS .START ./ .YES .TO .SAVE

1 . .Press .START / YES .to .accept .the .default .amount, .

or .use .the .arrow .keys .to .enter .a .desired .amount .and .

press .START / YES.

Add Oil to the Vacuum Pump

IMPORTANT: The vacuum pump is shipped

without oil in the reservoir. Failure to add oil to

the vacuum pump will damage the pump.

The .unit .displays

ADD .5 .OZ .OF .NEW .OIL

TO .VACUUM .PUMP

START .TO .CONTINUE

1 . .Remove .the .brass .plug .from .the .vacuum .pump .oil .

fill .port . .See .Figure .2 .

2 . .Attach .the .flexible .tube/cap .to .the .oil .bottle; .pour .only

five .(5) .ounces .of .vacuum .pump .oil .into .the .fill .port . .

Note: You will top off the oil in the next step as the

vacuum pump is running.

3 . .Press .and .release .the .START / YES .key . .While .the .

vacuum .pump .is .running, .slowly .add .oil .until .the .

level .rises .to .the .center .of .the .reservoir’s .sight .glass .

4 . .Press .the .STOP / NO .key .to .stop .the .vacuum .pump, .

and .install .the .brass .plug .in .the .fill .port .

5 . .Press .START / YES .to .continue .

Setup

Figure 2

CAUTION: The unit is programmed

to run the setup procedure as outlined

here. To prevent personal injury, do

NOT operate the unit at any other

time without the brass plug installed,

because the vacuum pump is

pressurized during normal operation.

Sight Glass

Fill Port

Sight

Glass

Fill Port

Vacuum Pump