4

Menu Functions

1 . .Press .the .MENU .button .on .the .keypad .
2 . .Press .the .UP .or .DOWN .arrow .key .to .scroll .

through .the .menu .choices .shown .on .the .second .

line .of .the .display .:

. SELECT .LANGUAGE

. VERSION .X .XX

. SELECT .UNITS

. MAINTAIN .VACUUM .OIL

. MAINTAIN .FILTER

. REFRIG .MANAGEMENT

. MANUAL .REFILL

. ADJUST .TANK .FILL .LVL

. CALIBRATION .CHECK

. SERVICE .MENU

. DISPLAY .TANK .INFO
3 . .Press .START / YES .to .make .a .choice .from .the .

menu . .Press .STOP / NO .to .pause .during .any .

process, .and .STOP / NO .a .second .time .to .exit .

a .process .

Introduction

Select Language

Operator .may .choose .to .have .prompts .displayed .in .one .of .three .

languages: .English, .Spanish, .or .French .

Version X.XX

Displays .the .revision .level .of .the .software .in .the .unit .

Select Units

The . operator . may . choose . to . have . test . results . displayed . in .

Imperial .(lb .), .Imperial .(lb . .and .oz .), .or .Metric .(kg) .

Maintain Vacuum Oil

For .maximum .vacuum .pump .performance, .change .vacuum .

pump .oil .after .every .10 .hours .of .operation . .This .menu .item .

displays .how .long .the .vacuum .pump .has .operated .since .the .

last .oil .change, .and .allows .the .user .to .reset .the .value .once .an .

oil .change .is .complete . .Refer .to .the .instructions .outlined .in .the .

Maintenance .section .under .Change Vacuum Pump Oil .

Maintain Filter

The . filter-drier . removes . acid, . particulates, . and . moisture .

from . the . refrigerant . . To . meet . SAE . J-2788 . requirements, .

it . is . mandatory . to . replace . the . filter-drier . after . 150 . lbs . .

(68 .kg) .of .refrigerant .has .been .filtered . .This .menu .item .shows .

how .much .refrigerant .has .been .filtered .since .the .last .filter .change, .

and .allows .the .user .to .reset .the .value .once .a .filter .change .is .

complete . .A .code, .which .appears .on .the .filter, .must .be .entered .

into .the .unit .to .ensure .compliance .with .SAE .J-2788 . .Refer .

to .the .instructions .outlined .in .the .Maintenance .section .under .

Replace the Filter-Drier .

Refrig Management

Displays .the .amount .of .refrigerant .recovered, .charged, .and .

replenished .(for .the .life .of .the .unit), .and .filtered .(since .the .last .

filter .change) .

Manual Refill

Use .to .transfer .refrigerant .from .the .source .tank .to .the .internal .

storage . vessel . (ISV) . . Refer . to . instructions . outlined . in . the .

Maintenance .section .under .Manually Fill the ISV .

Adjust Tank Fill Lvl

During .the .tank .refill .process, .the .unit .stops .refilling .when .it .

reaches .the .pre-set .amount .of .refrigerant .in .the .internal .storage .

vessel .(default .is .15 .lbs .) . .This .value .may .be .adjusted .up .or .

down .to .suit .the .user’s .needs . .Refer .to .instructions .outlined .in .

the .Maintenance .section .under .Adjust Tank Fill Level .

Calibration Check

Use .to .verify .internal .scale .calibration . .Refer .to .instructions .in .

Maintenance .section .under .Scale Calibration Check .

Service Menu

For .Robinair .service .center .use .only .

Display Tank Info

Displays .internal .storage .vessel .(ISV) .pressure .and .temperature . .

Use .to .check .the .ISV .for .excessive .pressure .

Arrow

Keys

Start / Yes

Button

Stop / No

Button

Menu

Button

START /

YES

STOP /

NO

RECOVER

VACUUM

CHARGE

MENU