beautypg.com

Operating instructions – Robinair 34288 Recovery, Recycling, Recharging Unit User Manual

Page 12

background image

10

Recharge the A/C System

1 . .Press .CHARGE . Open .the .appropriate .panel .valve(s), .

depending .on .where .the .system .should .be .charged .– .

high-side, .low-side, .or .both .

2 . .Press .CHARGE again .to .change .the .units .of .

measure . .Accept .the .default .weight .by .pressing .

START / YES, .or .use .the .arrow .keys .to .scroll .to .the .

correct .amount, .and .press .START / YES .

3 . .The .display .reads

CHARGE .IN .PROGRESS ./ .DO .NOT .DISTURB

X .XX .LBS . .(X .XX .KG)

. Moving .or .bumping .the .unit .at .this .point .may .result .

in .an .incorrect .reading .

Note:
• During a charge cycle, if the unit fails to transfer

refrigerant due to low tank pressure, the charge

process is automatically interrupted and the unit

operates in a mode to build tank pressure. Once

tank pressure is sufficient, the unit automatically

completes the charge.

• When the charge cycle gets close to the weight

entered in Step 2, the unit slows down. It’ll charge,

settle, charge again, settle, etc.

4 .When .the .charge .is .complete, .the .display .reads

CHARGED .XXX .LBS .(KG)

PRESS .START .TO .EQUALIZE .HOSES

. The .user .must .equalize .pressure .in .the .service .hoses .

to .ensure .all .liquid .refrigerant .trapped .in .the .hoses .is .

transferred .to .the .vehicle .A/C .system .for .an .accurate .

charge . .Press .START / YES .to .equalize .hoses .

5 . .Close .the .high-side .coupler .valve . .The .display .reads

DISCONNECT .HS .HOSE

OPEN .PANEL .VALVES

AND .START .A/C .MAX

START .TO .CONTINUE

. The .high-side .hose .must .be .removed .from .the .

vehicle, .and .the low-side hose must stay

connected to the vehicle .with .the .low-side .

coupler .open .

6 . .Open .both .panel .valves .

Operating Instructions

Operating Tips

• After selecting the CHARGE function and

entering a desired weight, if the weight

entered will leave less than 2 lbs. (.91 kg) of

refrigerant in the internal tank after charge,

the charge function will not start. The display

reads

INSUFFICIENT .REFRIG .

PRESS .ANY .KEY .TO .EXIT

Refer to the Maintenance section of this

manual for instructions to Manually Refill the

Internal Storage Vessel (ISV).