beautypg.com

Operating instructions – Robinair 34288 Recovery, Recycling, Recharging Unit User Manual

Page 11

background image

9

543175 Rev. H, June 25, 2013

Evacuate the A/C System

1 . .Ensure .service .hoses .are .connected, .and .coupler .

valves .are .OPEN .

2 . .Press .VACUUM .
3 . .Press .START / YES .to .accept .the .default .evacuation .

time .of .10 .minutes, .or .enter .the .desired .vacuum .time .

using .the .number .keys, .and .press .START / YES .

IMPORTANT: The unit pulls a vacuum on the

vehicle A/C system to remove air and boil off

moisture that may be present in the system.

Evacuate the system for at least 10 minutes,

or follow the A/C system manufacturer’s

specifications, to ensure adequate moisture

and contaminant removal.

4 . .The .unit .evacuates .the .A/C .system .and .stops .when .

the .specified .amount .of .time .has .elapsed .

. Press .STOP / NO .to .pause .the .process . .Press .

START / YES .to .resume, .or .STOP / NO .again

to .exit .

You .are .now .ready .to .replenish .the .A/C .system .with .

new .oil, .if .necessary, .or .to .recharge .the .system .with .

refrigerant .

Operating Instructions

Operating Tips

If the vacuum pump has run for 10 or more

hours without an oil change, the unit displays

VACUUM .OIL .TIME .XX:XX

CHANGE .OIL .NOW?

Refer to instructions outlined in the Maintenance

section under Change Vacuum Pump Oil.

Before the unit begins evacuating the A/C

system, it checks for any pressure in the

system that might damage the vacuum pump.

If pressure is detected, the unit displays

PRESSURE .EXISTS

PRESS .ANY .KEY .TO .EXIT

Press any key to exit, and recover refrigerant

before proceeding.