Repl.

Component

Part No.

Filter-Drier .

34724

Service .Coupler .Set . .

. .(high- and low-side couplers) .

18192

Service .Hose .Set .

. .(high- and low-side hoses) . .

34722

Vacuum .Pump .Oil . .

. .(case of 12 quarts) .

13203

Vacuum .Pump .Oil . .

. .(case of 4 gallons) .

13204

Maintenance .Kit .

13172

Vinyl .Dust .Cover .(optional) .

17492

Tank .Adapter .

16301

Replacement Parts

Maintenance

Scale Calibration

The .calibration .check .is .used .to .ensure .the .unit’s .internal .

scale .is .always .calibrated . .During .this .test, .use .only .the .

calibration .weight .that .is .provided .with .the .unit .
1 . .Press .Menu .
2 . .Use .the .arrow .keys .to .scroll .to .CALIBRATION .

CHECK .

3 . .Refer .to .Figure .11, .and .verify .the .magnet .on .the .

bottom .of .the .unit .is .clean . .Press .START / YES .

4 . .The .display .reads .

ATTACH .THE .WEIGHT .TO .THE .BOTTOM .OF .THE .

MACHINE

PRESS .START .TO .CONTINUE

5 .Attach .the .weight .provided .to .the .magnet .on .the .

bottom .of .the .unit . .Press .START / YES .

Magnet

• . If .the .display .shows .CALIBRATION .APPROVED, .the .scale .is .in .calibration . .Press .any .key .to .exit .
• . If .the .display .shows .CALIBRATION .REJECT, .the .scale .is .out .of .calibration . .Call .your .local .service .

center .for .assistance .

• . If .the .display .shows .CALIBRATION .ERROR .1, .verify .the .calibration .weight .is .correctly .attached .

to .the .magnet, .and .verify .the .magnet .is .clean .with .nothing .attached .to .it . .If .that .does .not .correct .the .

problem, .call .your .local .service .center .for .assistance .

Tank Recertification

The .internal .storage .vessel .(ISV) .in .this .unit .is .a .

DOT-approved .tank .that .carries .a .date .code . .ISVs .

must .be .recertified .every .five .years .
To .determine .the .date .code .of .the .ISV .in .your .

Robinair .unit, .remove .the .front .panel .of .the .unit . .It .

should .be .possible .to .read .the .date .code .stamped .on .

the .ISV .
If .the .date .code .reads .beyond .the .five-year .limit, .

contact .a .Robinair .service .center .for .assistance .

Figure 11