Change Vacuum Pump Oil

For .maximum .vacuum .pump .performance, .change .the .

vacuum .pump .oil .after .every .10 .hours .of .operation . .(The .

unit .will .display .a .prompt .after .10 .hours .of .operation .)
1 . .Press .MENU . .Use .the .arrow .keys .to .select .

MAINTAIN .VACUUM .OIL, .and .press .START /

YES . .The .display .shows .how .long .the .vacuum .pump .

has .operated .since .the .last .oil .change:

PUMP .OIL .TIME .X:XX

TIME .REMAINING .X:XX

CHANGE .OIL?

2 . .Press .START / YES . .The .display .shows .VACUUM .

OIL .CHANGE .TIME .2:00, .and .counts .down .to .zero . .

Allow .the .vacuum .pump .to .run .until .it .automatically .

stops . .The .display .then .shows .DRAIN .OLD .OIL .

AND .ADD .5 .OZ .NEW .OIL .

3 . .Refer .to .Figure .10, .and .remove .the .brass .plug .from .

the .vacuum .pump’s .oil .fill .port . .(The .pump .drains .

faster .when .vented .)

4 . .Remove .the .oil .drain .fitting .cap, .and .drain .the .oil .into .

a .suitable .container .for .disposal . .Replace .the .cap .

5 . .Attach .the .flexible .tube .and .cap .to .the .oil .bottle; .pour .

five .(5) .ounces .of .vacuum .pump .oil .into .the .fill .port .

6 . .Press .START / YES . .The .display .shows .FILL .

PUMP .TO .CENTER .OF .SIGHT .GLASS, .and .the .

vacuum .pump .starts . .While .the .vacuum .pump .is .

running, .slowly .add .oil .until .the .level .rises .to .the .

center .of .the .reservoir’s .sight .glass .

7 . .Press .STOP / NO . .The .counter .resets .to .zero .after .a .

vacuum .pump .oil .change .has .been .completed . .

8 . .Replace .the .brass .plug .on .the .fill .port . .Press .STOP /

NO .to .exit .to .the .Main .Menu .

CAUTION: To prevent personal injury, do

NOT operate the unit at any time without the

brass plug installed, because the vacuum

pump is pressurized during normal operation.

Review the laws in your jurisdiction

to determine the correct disposal

procedure for pump oil. It is the

responsibility of the user to determine

if a material is a hazardous waste at

the time of disposal. Ensure you are

in compliance with all applicable laws

and regulations.

Maintenance

Oil Drain Fitting

Oil Fill Port

Sight Glass

Figure 10