Introduction

Robinair .No . .34288 .is .used .on .R-134a .vehicles .and .is .designed .to .be .compatible .with .existing .service .

equipment .and .standard .service .procedures . .Model .No . .34288 .is .a .UL-listed, .single-pass .system .

that .meets .SAE .specifications .for .recycled .refrigerant . .Follow .the .SAE-J2211 .recommended .service .

procedure .for .the .containment .of .R-134a .
The .unit .includes .a .1 .5 .cfm .(42 .l/m) .Robinair .high .vacuum .pump .for .fast, .thorough .evacuation . .The . .

compressor .pulls .the .A/C .system .to .0 .psig, .then .works .in .series .with .the .vacuum .pump .to .achieve .highly .

efficient .recovery .and .immediate .recharge . .If .the .system .is .not .opened .for .service, .there .is .no .need .to .pull .

additional .vacuum . .If .the .system .is .opened .for .service, .use .the .unit’s .vacuum .cycle .to .remove .air .and .

moisture .from .the .A/C .system . .(We .recommend .a .minimum .15-minute .vacuum, .or .follow .the .vehicle .

manufacturer’s .specs .) .Note: R-134a systems require special oils. Refer to the A/C system manufacturer’s

service manual for oil specifications.

Technical Specifications

Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . .115V, .60 .Hz .
Operating Range . . . . . . 50° .to .120° .F .(11° .to .49° .C)
Filter-Drier . . . . . . . . . . . . . . . . . 43 .cu . .in . .spin-on .type

Pump Free-Air Displacement . . . . .1 .5 .cfm .(42 .l/m)
Dimensions .

. . . . . . . . . . . . . .

49" .H .x .34" .W .x .23" .D

.

. . . . . . . . . . . . . . . (124 .5 .cm .x .86 .4 .cm .x .58 .4 .cm)

Digital Display: visual

interface between operator

and machine.

Main Power Switch: supplies

electrical power to unit.

Manifold Gauges:

connect to vehicle A/C system;

show system’s low-side and

high-side pressure.

Tool Storage Area

(additional storage

on back side for

extra filter-driers and

oil bottles).

Panel Valves:

direct system’s low-side

and high-side pressure.

Power Cord