15. Set the GAS/ELEC switch to either GAS for a gas/oil heating
system or ELEC for an electric heating system (Figure 6).
16. Replace thermostat cover by snapping into place.
17. Turn on power to system. Test thermostat as described in the
following section.
6
GAS/ELECTRIC
Switch
Figure 6
TERMINAL LEGEND - 9415
TERM
EQUIPMENT TO CONNECT
REQ?
TERMINAL FUNCTION
C
24VAC common connection
Yes
For input of 24VAC common
side of transformer
R
24VAC hot connection
Yes
For input of 24VAC hot side
of transformer
Y2
Second stage cooling connection
No
Energizes on a call for
second stage cooling (aux.)
Y1
First stage compressor connection
Yes*
Energizes on a call for first
stage of cooling
W1
First stage heat connection
Yes*
Energizes on a call for first
stage of heating
W2
Second stage heat connection
No
Energizes on a call for
second stage heating (aux.)
G
Indoor fan connection
Yes
Energizes with W1, W2, Y1
and Y2 terminals or with
FAN option switched to the
ON position
O
Accessory**
No
Energizes when in the in
COOL mode
B
Accessory**
No
Energizes when in the
HEAT or EM modes
*
This thermostat can be used as a heat only or cool only thermostat therefore it is not always
necessary to use both W1 and Y1.
** The O and B terminals are accessory terminals that typically are used for zoning applications.