Robertshaw PTC-4200 Series User Manual
Robertshaw Water boiler
Specifications
Setpoint
Part
Type
Adjustment
Number
Range
°F (°C)
PTC-4111
*
-40 to 120 (-40 to 49)
PTC-4111-020
**
-40 to 120 (-40 to 49)
PTC-4112
Single-Stage
100 to 260 (38 to 127)
PTC-4121
Single-Bulb
-40 to 120 (-40 to 49)
PTC-4122
100 to 260 (38 to 127)
PTC-4123
190 to 350 (88 to 176)
PTC-4211
†
-40 to 120 (-40 to 49)
PTC-4221
Two-Stage
-40 to 120 (-40 to 49)
PTC-4222
Single-Bulb
100 to 260 (38 to 127)
PTC-4223
190 to 350 (88 to 176)
Dimensions
Safe Bulb
Capillary
Bulb
Differential
Temperature
Copper
Copper
°F (°C)
Range
ft. (m)
in. (mm)
°F (°C)
8 (2.4)
20 (6)
8 (2.4)
10 (3) Armored
10 (3) Armored
10 (3) Armored
8 (2.4)
10 (3) Armored
10 (3) Armored
10 (3) Armored
3/8" dia. x 4"
(9.5 mm x 102 mm)
Factory Set 3 (2)
Adj. 3 to 16 (2 to 9)
-40 to 170 (-40 to 77)
-40 to 170 (-40 to 77)
-40 to 310 (-40 to 154)
-40 to 170 (-40 to 77)
-40 to 310 (-40 to 154)
-40 to 400 (-40 to 204)
-40 to 170 (-40 to 77)
-40 to 170 (-40 to 77)
-40 to 310 (-40 to 154)
-40 to 400 (-40 to 204)
Per Stage Fixed 3 (2)
Between Stages
Set 3 (2)
Adj. 2 to 10 (1 to 5)
PTC-4100 Series & PTC-4200 Series Bulb Thermostats
* PTC-4111 replaces Johnson A19ABC-24,White Rodgers 1609-12, -13
** PTC-4111-020 replaces Johnson A19ABC-36
† PTC-4211 replaces Johnson A28AA-29
®