beautypg.com

ADTRAN 1200070L1 User Manual

Page 149

background image

Appendix B: Log Messages

61200.070L1-1

Express XL/XLT User Manual

133

NOT end2end ISDN
level 4
The path that the call was routed over is not ISDN from end-to-end. This is a
warning and is most often seen for POTS calls.

Power Up - last down cause:
level 0 (displayed as level 1 after the unit is reset)
This is the for the last reset. Most are caused by internal errors. Pos-
sible reasons are:

Bus Error

- Bad address occurred on the internal bus

Kernel error

- General operating system error

No SBCs

- Mail resources used up or lost

Router stack error

- Fatal error in protocol stack

general panic

- general error

no rip

- rip tasks could not start

out of memory

- out of available memory

out of TCP ports

- all TCP ports are used up

unknown error

- unknown fatal error has occurred

Set timer error

- Cannot set real time clock

Software Watch Dog Reset

- Software watchdog was not updated

Probe: all ports busy
level 3
All ports were busy when it was time to probe. An attempt will be made on
the next probe interval.

Probe failed
level 2
An attempt to connect to a probe site failed.

Probing
level 4
The Express XL/XLT is making an outgoing call to the destination specified
by the description in the Connection List in order to get an update on routes.

POTS call bump
level 4
The Express XLT has dropped bandwidth on an existing data call so that a
POTS call can be connected.