9040 Classic for REA & M90 Systems - Maintenance

3 0

3 0

3 0

3 0

3 0

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

AC Power ON

AC Power ON

AC Power ON

AC Power ON

AC Power ON
Indicator (Green

Indicator (Green

Indicator (Green

Indicator (Green

Indicator (Green
LED) Does Not

LED) Does Not

LED) Does Not

LED) Does Not

LED) Does Not
Light when ON/OFF

Light when ON/OFF

Light when ON/OFF

Light when ON/OFF

Light when ON/OFF
Switch is ON

Switch is ON

Switch is ON

Switch is ON

Switch is ON

No or Low kV

No or Low kV

No or Low kV

No or Low kV

No or Low kV
Output at Spray

Output at Spray

Output at Spray

Output at Spray

Output at Spray
Applicator when HV

Applicator when HV

Applicator when HV

Applicator when HV

Applicator when HV
ON Indicator (Red

ON Indicator (Red

ON Indicator (Red

ON Indicator (Red

ON Indicator (Red
LED) is Lit

LED) is Lit

LED) is Lit

LED) is Lit

LED) is Lit

1. Front panel fuse 1FU or PC board

fuse F2 defective

2. Connector 7PL or 9PL not properly

plugged into main PC board

3. Improper input line voltage

4. Improper exhaust fan or conveyor

interlock connections

5. Defective ON/OFF switch 1SW

6. Defective power supply 1SUP

7. Defective LED display board

1. High voltage adjust knob not set to

proper value

2. Connector 6PL or 1PL not properly

plugged into respective locations

3. Defective spray applicator or high

voltage cable

4. Loose or broken wire in power

supply

5. Main PC board defective

6. Defective high voltage multiplier

General Problem

General Problem

General Problem

General Problem

General Problem Possible Cause

Possible Cause

Possible Cause

Possible Cause

Possible Cause

Solution

Solution

Solution

Solution

Solution

1. Replace defective fuse.

2. Properly attach connector.

3. Ensure voltage across terminals L1 and N of

terminal block 1TB is between 90 and 264
VAC.

4. Correct connection so that voltage across

terminals L2 and N of 1TB is between 90 and
264 VAC.

5. Voltage across terminals 1A and 2A of ON/

OFF switch 1SW should be between 90 and
264 VAC. If not, replace switch 1SW.

6. Voltage across terminals 2 and 3 of plug 7PL

on main PC board should be 18 VDC. If not,
replace power supply 1SUP.

7. If all other functions of power supply are

normal, replace LED display board.

1. Set high voltage adjust knob to proper value.

2. Properly attach connector.

3. Perform a kV Output Test on the power supply.

If proper readings are obtained, check cable or
spray applicator for cause (see spray applicator
service manual).

4. Check all wiring connections for integrity.

Repair wiring as needed.

5. Disconnect 1PL from high voltage multiplier

and plug into LTST5000 Tester. If improper
readings are obtained, replace main PC board.

6. Disconnect HV cable from power supply. If

problem is still present, connect LTST5000
Tester to 1PL and test. If results of test are
OK, replace High Voltage Multiplier.

(Continued On Next Page)