INTRODUCTION
DESCRIPTIONS
The
MCV 2 Collet Series Dual Purge Color
Changer is designed with either English or Metric
dual fluid lines to take advantage of the true dual
purge capabilities of the applicators; Evolver and
RMA-202. The design of these applicators allows
the spraying under voltage of one side while the
other side is being cleaned with no loss of voltage
during the spray. Also, included with this assem-
bly is a solvent/air purge block.
The 78949-00 microvalve was designed to trigger
up to 2-million cycles. The fluid and air sections
are separated by a weep port to prevent contam-
ination between air and fluid.
SPECIFICATIONS
Operating Pressure:
Fluid
300 psi max. (20.68 bar)
Operating Temperature
Range:
55°F (12.8°C)
130°F (54°C)
Fluid Tube (Metric):
Inlet
10mm ODT
Circulation
8mm ODT
Solvent/Air Purge
10mm ODT
End Plate Outlet
1/4-inch NPSM “AN”
Style
Air Tube (Metric):
Actuation
4mm ODT Inlet
Fluid Tube (Fraction):
Inlet
3/8-inch ODT
Circulation
5/16-inch ODT
Solvent/Air Purge
3/8-inch ODT
End Plate Outlet
1/4-inch NPSM “AN”
Style
Air Tube (Metric-Fraction):
Actuation
5/32-inch
(4mm)
ODT
Inlet
Air Actuating
Pressure:
75-120 psi (5.2-8.3 bar)
Maximum Number
of Colors:
32
Construction Materials:
Stainless Steel
UHMW
Electrical / Physical