Be careful of residual fluid pressure or
solvent pressure in the line. Cover the area
where the valve slice is being removed to
prevent any solvent or paint from spraying
out.
W A R N I N G
!
4. Pull out the 1/2-inch clip as shown in Figure 13.
5. Loosen and remove any mounting bolts hold-
ing the stack in place.
6. Carefully pull the stack assembly ends apart
and remove the valve block.
>
Prior to servicing the unit, insure that all
fluid pressure is relieved to atomsphere. A
solvent purge should be performed if pos-
sible.
W A R N I N G
!
Figure 12: Tube Removal
Tube Removal
The 5/32-inch (4mm) trigger line tubes may be
removed by hand by pushing on the collet while
pulling out the tube. A tool is required to remove
both the 5/16-inch (8mm) and 3/8-inch (10mm)
tube. To remove the 10mm tube, use the black
inserted end of the tool. For the 8mm tube, use
the white inserted end. First remove the red clips
then press the tool against the collet in the block.
With the collet pushed in , pull out the tube that
is being removed (see Figure 12).
TUBING
REMOVING AND
REINSTALLING A VALVE
BLOCK FROM A STACK
1. Insure all pressure is bled off the system. If
possible, flush the block with appropriate solvent.
2. Using the clip removal tool (78078-00), push
on the installed locking clip with the “V” cut as
shown in Figure 13.
3. Push the upper locking clip out of the locking
slots using the removal tool.
7. Replace the valve slice, push the assembly
together, and insert the locking clips.
Figure 13: Removing and Reinstalling Valve
Block from a Stack
MCV 2 Dual Purge Color Changer - Maintenance