beautypg.com

Ransburg – Ransburg MCV2 Dual Purge Color Changer A10986-XX_A10993-XX User Manual

Page 20

background image

>

Be careful of residual fluid pressure or

solvent pressure in the line. Cover the area

where the valve slice is being removed to

prevent any solvent or paint from spraying

out.

W A R N I N G

!

4. Pull out the 1/2-inch clip as shown in Figure 13.

5. Loosen and remove any mounting bolts hold-

ing the stack in place.

6. Carefully pull the stack assembly ends apart

and remove the valve block.

>

Prior to servicing the unit, insure that all

fluid pressure is relieved to atomsphere. A

solvent purge should be performed if pos-

sible.

W A R N I N G

!

Figure 12: Tube Removal

Tube Removal

The 5/32-inch (4mm) trigger line tubes may be

removed by hand by pushing on the collet while

pulling out the tube. A tool is required to remove

both the 5/16-inch (8mm) and 3/8-inch (10mm)

tube. To remove the 10mm tube, use the black

inserted end of the tool. For the 8mm tube, use

the white inserted end. First remove the red clips

then press the tool against the collet in the block.

With the collet pushed in , pull out the tube that

is being removed (see Figure 12).

TUBING

REMOVING AND

REINSTALLING A VALVE

BLOCK FROM A STACK

1. Insure all pressure is bled off the system. If

possible, flush the block with appropriate solvent.

2. Using the clip removal tool (78078-00), push

on the installed locking clip with the “V” cut as

shown in Figure 13.

3. Push the upper locking clip out of the locking

slots using the removal tool.

7. Replace the valve slice, push the assembly

together, and insert the locking clips.

Figure 13: Removing and Reinstalling Valve

Block from a Stack

MCV 2 Dual Purge Color Changer - Maintenance

17

CS-05-01.9

Ransburg