beautypg.com

Ransburg, Mcv 2 dual purge color changer - safety – Ransburg MCV2 Dual Purge Color Changer A10986-XX_A10993-XX User Manual

Page 5

background image

Spray Area

AREA

Tells where hazards

may occur.

HAZARD

Tells what the hazard is.

SAFEGUARDS

Tells how to avoid the hazard.

Fire Hazard

Improper or inadequate

operation and maintenance

procedures will cause a fire

hazard.

Protection against inadver-

tent arcing that is capable of

causing fire or explosion is

lost if any safety interlocks

are disabled during opera-

tion. Frequent Power Supply

or Controller shutdown indi-

cates a problem in the system

requiring correction.

Fire extinguishing equipment must be present in

the spray area and tested periodically.

Spray areas must be kept clean to prevent the

accumulation of combustible residues.

Smoking must never be allowed in the spray

area.

The high voltage supplied to the atomizer must

be turned off prior to cleaning, flushing or main-

tenance.

When using solvents for cleaning:

Those used for equipment flushing should

have flash points equal to or higher than

those of the coating material.

Those used for general cleaning must have

flash points above 100°F (37.8°C).

Spray booth ventilation must be kept at the rates

required by NFPA-33, OSHA, country, and local

codes. In addition, ventilation must be main-

tained during cleaning operations using flam-

mable or combustible solvents.

Electrostatic arcing must be prevented. Safe

sparking distance must be maintained between

the parts being coated and the applicator. A dis-

tance of 1 inch for every 10KV of output voltage

is required at all times.

Test only in areas free of combustible material.

Testing may require high voltage to be on, but

only as instructed.

Non-factory replacement parts or unautho-

rized equipment modifications may cause fire or

injury.

If used, the key switch bypass is intended for

use only during setup operations. Production

should never be done with safety interlocks dis-

abled.

Never use equipment intended for use in water-

borne installations to spray solvent based ma-

terials.

The paint process and equipment should be

set up and operated in accordance with NFPA-

33, NEC, OSHA, local, country, and European

Health and Safety Norms.

MCV 2 Dual Purge Color Changer - Safety

2

CS-05-01.9

Ransburg