Figure 5: Grounding the Color Changer

Grounding of the Color Changer

For safety, the color changer MUST be grounded.

Using a 12-gauge wire, ground the output plate

metal mounting screw of the color changer to a

true earth ground. Using an ohm meter, check

for ground, testing the earth ground to the purge

assembly top plate. The resistance should be 10

ohms or less (see Figure 5).

> The color changer MUST be properly

grounded. Proper grounding (as described

below) will prevent static charge buildup and

possible discharge from the color changer.

W A R N I N G

!

NOTE

> Use metal screws for mounting for

grounding purposes.

END PLATE BOLT

OHMS

EARTH GROUND

(TRUE)

10

0