Table 3 - Node Adapter + LECU4012-00
PLC I/O - Flex Mode (Dipswitch SW2-1 and SW2-5 On) (Cont.)
Add additional inputs from AirTronics Module as required.
0/00-07
0/10
11
12
13
14
15
16
17
1/00
01
02
03
04
05
06
07
1/10-17
WORD/
BIT
MODULE
INPUT
----
AirTronic 1
AirTronic 1
AirTronic 1
AirTronic 1
AirTronic 1
AirTronic 1
AirTronic 1
AirTronic 1
AirTronic 2
AirTronic 2
AirTronic 2
AirTronic 2
AirTronic 2
AirTronic 2
AirTronic 2
AirTronic 2
AirTronic 3
(Not Used)
Channel 1 Low Tolerance Alarm
Channel 1 High Tolerance Alarm
Channel 2 Low Tolerance Alarm
Channel 2 High Tolerance Alarm
Input Pressure Low Alarm (<75 psi)
Input Pressure High Alarm (>95 psi)
Internal Communication Fault
Hose Fault
Channel 1 Low Tolerance Alarm
Channel 1 High Tolerance Alarm
Channel 2 Low Tolerance Alarm
Channel 2 High Tolerance Alarm
Input Pressure Low Alarm (<75 psi)
Input Pressure High Alarm (>95 psi)
Internal Communication Fault
Hose Fault
(Additional AirTronic Modules)
DISCRETE INPUT CONFIGURATION
* See "Configuration Word Construction" in Appendix 1.
** If no SerAT Modules Installed, next module type moves to this position.
*** See following "Tolerance Word Construction."
Serial Node Adapter/Serial Node Adapter + - Operation
Ransburg
26