Table 3 - Serial Node Adapter + LECU4012-00

PLC I/O - Flex Mode (Dipswitch SW2-1 and SW2-5 On)

BTW

WORD MODULE

BTW BLOCK CONFIGURATION

0

1

2

3

4

5

6

7

8

9

X

X

X

X

X

X

X

Motherboard 0

Motherboard 1

Motherboard 2

Motherboard 3

MicroPak

MicroPak

MicroPak

----

SerAT 1**

----

SerAN 1

SerAN 1

----

AirTronic 1

AirTronic 1

AirTronic 1

----

Configuration word defining Motherboard 0 Modules *

Configuration word defining Motherboard 1 Modules *

Configuration word defining Motherboard 2 Modules *

Configuration word defining Motherboard 3 Modules *

High Voltage Setpoint: (Value of 0-100 corresponds to 0-100 KV)

Current Limit Setpoint:

HP404 Cascade: 0-250 corresponds to 0-250 µA

RP1000 Cascade: 0-1000 corresponds to 0-1000 µA

Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)

(Not Used)

Speed Setpoint:

Liquid: 0-50 corresponds to 0-50 krpm

(Additional Serial Atomizer(s) with higher slot addresses)

Channel 1 Setpoint (Value of 10-100 corresponds to 0-90 psi)

Channel 2 Setpoint (Value of 10-100 corresponds to 0-90 psi)

(Additional Serial Analog(s) with higher slot addresses)

Channel 1 Setpoint (Enter in slpm, e.g. to set 85 slpm, enter 85)

Channel 2 Setpoint (Enter in slpm, e.g. to set 85 slpm, enter 85)

High / Low Flow Tolerance (0-15 equals 0-30% of setpoint) ***

(Additional AirTronic modules(s) with higher slot addresses)

BLOCK TRANSFER WRITES

* See "Configuration Word Construction" in Appendix 1.

** If no SerAT Modules Installed, next module type moves to this position.

*** See following "Tolerance Word Construction."

Serial Node Adapter/Serial Node Adapter + - Operation

Ransburg

18

LN-9238-02.3