Table 3 - Serial Node Adapter + LECU4012-00
PLC I/O - Flex Mode (Dipswitch SW2-1 and SW2-5 On)
BTW
WORD MODULE
BTW BLOCK CONFIGURATION
0
1
2
3
4
5
6
7
8
9
X
X
X
X
X
X
X
Motherboard 0
Motherboard 1
Motherboard 2
Motherboard 3
MicroPak
MicroPak
MicroPak
----
SerAT 1**
----
SerAN 1
SerAN 1
----
AirTronic 1
AirTronic 1
AirTronic 1
----
Configuration word defining Motherboard 0 Modules *
Configuration word defining Motherboard 1 Modules *
Configuration word defining Motherboard 2 Modules *
Configuration word defining Motherboard 3 Modules *
High Voltage Setpoint: (Value of 0-100 corresponds to 0-100 KV)
Current Limit Setpoint:
HP404 Cascade: 0-250 corresponds to 0-250 µA
RP1000 Cascade: 0-1000 corresponds to 0-1000 µA
Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)
(Not Used)
Speed Setpoint:
Liquid: 0-50 corresponds to 0-50 krpm
(Additional Serial Atomizer(s) with higher slot addresses)
Channel 1 Setpoint (Value of 10-100 corresponds to 0-90 psi)
Channel 2 Setpoint (Value of 10-100 corresponds to 0-90 psi)
(Additional Serial Analog(s) with higher slot addresses)
Channel 1 Setpoint (Enter in slpm, e.g. to set 85 slpm, enter 85)
Channel 2 Setpoint (Enter in slpm, e.g. to set 85 slpm, enter 85)
High / Low Flow Tolerance (0-15 equals 0-30% of setpoint) ***
(Additional AirTronic modules(s) with higher slot addresses)
BLOCK TRANSFER WRITES
* See "Configuration Word Construction" in Appendix 1.
** If no SerAT Modules Installed, next module type moves to this position.
*** See following "Tolerance Word Construction."
Serial Node Adapter/Serial Node Adapter + - Operation