Operation, Ransburg – Ransburg Serial Node Adapter LECU4002_78553 User Manual
Page 16

OPERATION
TABLE 1 - SERIAL NODE ADAPTER + LECU4012-00
PLC I/O - MICROPAK MODE
BTW
WORD MODULE
CONFIGURATION
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
MicroPak #1
MicroPak #1
MicroPak #1
----
MicroPak #2
MicroPak #2
MicroPak #2
----
MicroPak #3
MicroPak #3
MicroPak #3
----
MicroPak #4
MicroPak #4
MicroPak #4
----
High Voltage Setpoint (Value of 0-100 corresponds to 0-100 KV)
Current Limit Setpoint
HP404 Cascade: 0-250 corresponds to 0-250 µA
RP1000 Ccascade: 0-1000 corresponds to 0-1000 µA
Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)
(Not Used)
High Voltage Setpoint (Value of 0-100 corresponds to 0-100 KV)
Current Limit Setpoint
HP404 Cascade: 0-250 corresponds to 0-250 µA
RP1000 Cascade: 0-1000 corresponds to 0-1000 µA
Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)
(Not Used)
High Voltage Setpoint (Value of 0-100 corresponds to 0-100 KV)
Current Limit Setpoint
HP404 Cascade: 0-250 corresponds to 0-250 µA
RP1000 Cascade: 0-1000 corresponds to 0-1000 µA
Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)
(Not Used)
High Voltage Setpoint (Value of 0-100 corresponds to 0-100 KV)
Current Limit Setpoint
HP404 Ccascade: 0-250 corresponds to 0-250 µA
RP1000 Cascade: 0-1000 corresponds to 0-1000 µA
Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)
(Not Used)
BLOCK TRANSFER WRITES
Serial Node Adapter/Serial Node Adapter + - Operation
Ransburg
12
LN-9238-02.3