beautypg.com

Ransburg – Ransburg Serial Node Adapter LECU4002_78553 User Manual

Page 12

background image

Position 8:

This position enables a Bus Agreement Override

mode that allows the Serial Node Adapter/Serial

Node Adapter + to communicate between the

internal bus and the PLC when the two configura-

tions do not agree. In this mode the Serial Node

Adapter/Serial Node Adapter + will use the bus

configuration specified in the BTW configuration

word.

>

This mode should only be used for

troubleshooting. It is possible for data to

be communicated to the wrong module.

For this reason, bit 14 is set in the BTR

words 0, 1, and 2, indicating this

mode has been entered. The "CPU" in-

dicator on the Serial Node Adapter/Serial

Node Adapter + will flash also.

NOTE

1/4

1/2

3/4

Full

# SerDG

Modules

0 - 2

3 - 6

7 - 10

11 - 12

Rack Size

Figure 1: Position 6 & 7 Rack Size Settings

Figure 1: AdaptaFlow System Rack

Serial Node Adapter/Serial Node Adapter + - Introduction

Ransburg

8

LN-9238-02.3