RMA-303 Direct Charge - Maintenance
LN-9266-11.3
68
Bell Cup Removal
!
C A U T I O N
•
Failure to replace a damaged bell cup will
cause premature turbine failure. Warranty
will not be honored if the bell cup is dam-
aged.
N O T E
For removal of the 30mm or 55mm bell cups,
you must use bell cup wrench A11284-00. For
the 65mm bell cups you must use AA12061-00
bell cup wrench.
Bell Cup Wrenches
A11284-00 BELL CUP WRENCH
A12061-00 BELL CUP WRENCH
USE ON 30M AND 55MM BELL CUPS ONLY
USE ON 65MM BELL CUPS ONLY
To re-install a cup, position the wrench as
shown. Insert a torque wrench into the square
in the wrench to apply approximately 50-70
lbs•in (5.69-7.91 Nm) torque. Hold the cup
and tighten the torque wrench in a counter-
clockwise direction.
HOLD
BELL CUP
WITH ONE
HAND
CCW WITH
TORQUE
WRENCH
Bell Cup Installation
N O T E
There is a 3-inch center-to-center distance
between the bell cup and the 3/8-inch socket
square on the wrench. This distance must be
factored in when reading the proper torque on
the wrench.
Example: A desired true torque is desired
using a 9-inch effective length torque
wrench. Wrench offset is 3-inches.
L = 9-inches
TT = 50 lbs•in
E = 3-inches
DR = is dial reading.
DR = 50 (9) DR = 37.5 lbs•in
(9+3)