9060 for No. 2 Process Handgun - Operation

CP-13-04.2

20

SETPOINT
OPERATIONS

Voltage Setpoints

The voltage on the 9060 High Voltage Control-
ler is adjustable between 20 kV and full kV DC.
There are 3 voltage setpoints (presets); 1, 2,
and 3. Each of these setpoints can be individu-
ally adjusted between 20 kV and full kV DC.
The three (3) factory preset voltages are listed
in the following table:

The full kV DC value is determined by

the gun type configuration for the particu-
lar applicator that is being used, NOT the
full KV value of the cascade.

N O T E

Factory Presets

Preset

Value

1

Full kV minus 20 kV

2

Full kV minus 10 kV

3

Full kV

Setting the Setpoint

When the No. 2 Handgun is off, the present
setpoint can be changed by pressing the 1, 2,
or 3 buttons on the front panel shown in Figure
17. The setpoint that is currently selected will
have the LED light in the upper right corner of
the button lit.

Figure 17: kV Adjust/Setpoint Buttons

select the desired setpoint by pressing the
corresponding setpoint button. The setpoint
can then be adjusted between 20 kV and full
kV using the + and - buttons on the front panel
of the 9060 Controller shown in Figure 17.
Single pushes of the + or - buttons will incre-
ment or decrement the currently selected
preset in units of 1. When the + or - buttons
are held in for longer than a 1/2 second, the kV
display will begin incrementing or decrementing
in units of five (5).

Resetting Faults

During operation, various faults can occur
based upon the operating conditions or if any
problems with the 9060 unit arise. If a fault
occurs, to reset a fault, turn off the No. 2
Handgun and press the Reset Button . This will
clear the fault status and put the unit back into
operation unless a fault condition is still pre-
sent. Please refer to the “Fault Description”
portion of the Operation Section of this Service
manual for more information on a specific fault
and how to correct it.

FAULT DESCRIPTIONS


For in depth troubleshooting information on the
9060, please refer to the “Fault Troubleshoot-
ing” portion of the Maintenance Section of this
service manual.

If a fault occurs, the Fault

Indicator on the front of the Controller will light
and a fault code will be displayed on the
microamp display. Faults can be reset by
pressing the Reset button on the front of the
Controller or by using the remote I/O reset
signal.

Any fault code not listed that appear on

the screen are a likely indication of a PC
board failure due to possible arc damage.

N O T E

Adjusting Presets

To adjust one of the preset setpoints, ensure
the No. 2 Handgun is off in LOCAL mode and

There is a 5 second fault reset delay

timer that inhibits the triggering of high
voltage immediately after a fault reset.

N O T E