Safety ground, Input voltage selection, High voltage cable – Ransburg 9060 HV P.S. Air Motor 80102-31X User Manual
Page 19
9060 for No. 2 Process Handgun - Installation
CP-13-04.2
14
Adapter Plate using conduit and wire to TB1
as follows:
Hot/Line
to TB1-L1
Neutral/Common to TB1-N
Ground
to TB1-EARTH GROUND
Figure 5: Location of TB1 & TB2 in Controller
SAFETY GROUND
Crimp the appropriate connector onto the
ground wire assembly and install from the
Controller ground stud, located on the side
panel, to a true earth ground.
The ground wire assembly MUST be
connected from the Controller ground
stud to a true earth ground.
!
C A U T I O N
INPUT VOLTAGE
SELECTION
The 9060 Controller accepts universal input
voltage between 100 and 240 VAC at 50 or 60
Hz. There is no need to change any switch
settings when changing input from 110 to 240
VAC or from 240 to 110 VAC.
All 9060 units (80102-31X) shipped
from the factory for either 110 VAC input
or 240 VAC input will have a 72771-06, 1
Amp front panel fuses installed.
N O T E
Figure 6: Installation of Conduit Adapter Plate
HIGH VOLTAGE CABLE
Position the No. 2 Process Handgun in the
spray area and route the high voltage cable to
the Controller. The cable should be routed so
that it is not damaged by foot and vehicle traffic
and also so that is not close to areas of high
temperature (129°F+). The operator should
have free movement of the applicator and all
bend radii of the cable should not be less than 6
-inches (15 cm). Connect the high voltage
cable to the Controller and tighten the retaining
nut and set screw. If during the routing of the
high voltage cable it is required to remove it
from the No. 2 Handgun, care should be taken
when reinstalling so that the high voltage cable
is completely engaged.
The Controller MUST be OFF when the
No. 2 Handgun is removed or reinstalled.
!
W A R N I N G