LumaStream Trinity PERMANENT User Manual
Page 5

Document: 66APPMAN Rev: H
28 of 32
(1)TRINITY ANALOG, (1) COMMERCIAL DIMMING PANEL WITH (2)
0-10VDC ANALOG CONTROL SIGNALS
Note: This wiring configuration provides dimming control for zones 1 and 2
simultaneously and separate dimming control for zones 3 and 4
simultaneously with a commercial dimming interface comprising (2)
0-10Vdc control signals.
Document: 66APPMAN Rev: H
5 of 32
Table 6
TRINITY DMX Model Options
Model #
# of
Channels
Drive
Current
Output Voltage
Range (under
load Conditions)
Maximum #
of LEDs per
Channel
(typical)
66-12-0600-DMX-3
12
600mA
6 to 27 Vdc
2 to 8
66-12-0700-DMX-3
12
700 mA
6 to 27 Vdc
2 to 8
66-09-0800-DMX-3
9
800 mA
6 to 27 Vdc
2 to 8
66-09-0900-DMX-3
9
900 mA
6 to 27 Vdc
2 to 8
66-09-1000-DMX-3
9
1000 mA
6 to 27 Vdc
2 to 8
66-06-1200-DMX-3
6
1200 mA
6 to 27 Vdc
2 to 8
66-06-1400-DMX-3
6
1400 mA
6 to 27 Vdc
2 to 8
70-12-0300-DMX-3
12
300 mA
12 to 47 Vdc
4 to 12
70-12-0350-DMX-3
12
350mA
12 to 47 Vdc
4 to 12
70-09-0400-DMX-3
9
400 mA
12 to 47 Vdc
4 to 12
70-09-0500-DMX-3
9
500 mA
12 to 47 Vdc
4 to 12
70-06-0600-DMX-3
6
600 mA
12 to 47 Vdc
4 to 12
70-06-0700-DMX-3
6
700mA
12 to 47 Vdc
4 to 12
Table 5
Protection
Output Protection
Over voltage, over current, short circuit protection
Over Temperature
Protection
Power supply will shut down when external ambient
temperature exceeds 43ºC or case temperature
reaches 85ºC nominal
Output Interconnection
Protection
Hiccup Mode with automatic recovery upon removal of
short. Only applies to +ve to –ve interconnections.
Table 7
DMX Interface Specifications
Control Method
DMX512-A
DMX Receiver Isolation
Isolated from earth ground
Start Codes
Will only respond to NULL START code
Packet Processing Latency
5ms Typical
Will Handle “Short Slots?”
Yes
Number of Dimmers on single
DMX512 universe
Up to 64 Driver/Dimmers can be daisy chained via DMX
connector loop through
Loss of DMX Input Signal
Outputs will go to 100% light intensity in less than 1 sec-
ond