MOUNTING ORIENTATION
For sufficient cooling, the TRINITY LED Driver Dimmer must be mounted in
either a vertical or horizontal orientation as shown:
↑
UP
Vertical orientation
provides the best
cooling option
Recommended mounting screw size #8 machine or self tapping screw
↑
UP
↑
UP
Document: 66APPMAN Rev: H
23 of 32
11.2 Output Zone/Channel Connections Table
Either 6, 9, or 12 output channel options are available for driving and
dimming LEDs. Channels are assigned to zones as shown in the following
tables. A 6 or 9 channel option will provide 3 zones for dimming and a 12
channel option will provide 4 zones for dimming.
Zone Number
Output Channel
Belden/Alpha or Equivalent Wire Color/
Polarity
1
1
WHT + / BLK -
1
2
RED
+ / BLK -
1
3
GREEN
+ / BLK -
2
4
WHT + / BLK -
2
5
RED
+ / BLK -
2
6
GREEN
+ / BLK -
3
7
WHT + / BLK -
3
8
RED
+ / BLK -
3
9
GREEN
+ / BLK -
4
10
WHT + / BLK -
4
11
RED
+ / BLK -
4
12
GREEN
+ / BLK -
Zone Number
Output Channel
Belden/Alpha or Equivalent Wire Color/
Polarity
1
1
WHT + /
GREEN
-
1
2
RED
+ / BLK -
2
3
WHT + /
GREEN
-
2
4
RED
+ / BLK -
3
5
WHT + /
GREEN
-
3
6
RED
+ / BLK -