Thea 56 specifications – LumaStream THEA 56 User Manual
Page 2

THEA 56 Specifications
Input
Output
System Protection
Safety and EMI/EMC
Environmental
Control Interface
Rated Input Voltage
120 to 277 Vac
Rated Input Frequency
50/60 Hz
Power Factor EN61000-3-2
@120 Vac or 277 Vac 0.95 W/VA; 100% load
Input Current Total Harmonic Distortion @120 or 277 Vac 17% max, 100% load
Rated Output Power
58.8 W max
Efficiency
@240 Vac (no load on auxiliary output) 88% full load
System Power Cycle Delay
0.6 second typical
Output Current Tolerance
+/-5 % of nominal
Auxiliary Voltage
5 Vdc @ 400 mA, 12 Vdc @ 164 mA; less than 1% load/line regulation
Output
Over voltage, over current, short circuit protection
Over Temperature
Power supply will throttle back output current gradually when case
temperature reaches 80°C/176°F nominal.
Agency Approvals
UL 8750 Class 2 outputs, LVD EN61347-2-13, EN61347-1
Emissions
FCC Title 47, Part 15, EN55015; EN55022, Class B
Immunity
EN61547, EN55024
EMC
EN61000-3-2 (Class C); EN61000-3-3
Location Rating
IP50 Dry/Damp Location
Operating Ambient Temperature
-20°C to 55°C / -4°F to 131°F
Maximum Case Temperature
T
c
=75°C / 167°F
Storage Ambient Temperature
-40°C to 80°C/ -40°F to 176°F
Relative Humidity
5% to 95% noncondensing
Mean Time Between Failure
(MIL HDBK-217F)
>200,000 hours @ 65°C / 149°F
Control Method
Analog 0-10 Vdc, IEC 60929 Outputs 0.5 mA max or variable 0-10 Vdc
Voltage Source; Class 2 outputs.
Loss of Analog Input Signal
Outputs will go to 100% light intensity in less than 1 second
LSPS05 / THEA 56
© 2014 LumaStream
www.lumastream.com
+1 (727) 827-2805