beautypg.com

Wire sizing & gland sizing – Kasco Marine 4400EJ User Manual

Page 4

background image

4

Gland

O.D. of Cord

White

9-11mm

Black

11-13mm

Yellow

13-15mm

Kasco 50 Hz Equipment Wire Size Chart

Model

Cord Length

10m

30m

60m

90m

2400EVX

1.5mm

2

1.5mm

2

2.5mm

2

2.5mm

2

2400EJ

1.5mm

2

1.5mm

2

2.5mm

2

2.5mm

2

3400EVX

1.5mm

2

1.5mm

2

2.5mm

2

2.5mm

2

3400EJ

1.5mm

2

1.5mm

2

2.5mm

2

2.5mm

2

4400EVX

1.5mm

2

1.5mm

2

2.5mm

2

4mm

2

4400EJ

1.5mm

2

1.5mm

2

2.5mm

2

4mm

2

2400EVX, 2400EJ, 3400EVX,

4400EVX Parts

A. EV or EJ Aerating Fountain (Unit with cord or
stub cord) (1)
B. Float(with two 50’ mooring ropes attached) 1
C. 1/4-20 x 3 1/4” Phillips Pan Head Screw (4)
D. 1/4” (3/4” outer diameter) Flat Washer (4)
E. 3/8” Flat Washer (4)
F. 3/8”-16 Nylon Lock Nut (2)
G. 3/8”-16 x 1-3/8” Hex Head Bolt (2)
H. Bottom Screen Clips (2)
I. Nylon Cable Tie
J. Bottom Screen
K. Interchangeable nozzles for 2400EJF only
(See 2400EJF Nozzle Options section)

STEP SEVEN
Once the two subassemblies have been completed,
they can be joined together. Plug pin assembly into
the socket assembly and tighten the large blue nut
securely. The blue nut should be hand tightened only.
(See fi gure below).

Note: There is a small gap after tightening

For seasonal removal, your quick disconnect includes
an optional water tight cover. Simply separate the
quick disconnect and insert the sealing cover into the
large blue nut half and tighten fi rmly.

Strain Relief
The Strain Relief must be installed to protect the
Quick Disconnect from damage due to excessive
strain. The Strain Relief should be installed on the
user supplied cord length (not on the Kasco supplied
stub cord). It should be position about 15cm from the
Quick Disconnect. To install, insert the narrow end of
the elongated clamp with the chain connected into the
wide end of the short clamp. Use a rubber mallet to
tap the two pieces together securely. A Nylon Tie can
be used to keep it attached to the cord. The chain can
then be attached to the fl oat.

Wire Sizing & Gland Sizing

The chart below shows the proper Gland to be used
with different cord sizes. The measurements are based
on the Outside Diameter (O.D.) of the cord. Smooth,
round cords should be used.

Kasco Quick Disconnect 50 Hz Size Chart:

Gland

O.D. of Cord

Grey

7-9mm

This manual is related to the following products: